Line 124: |
Line 124: |
| ==Troubleshooting== | | ==Troubleshooting== |
| | | |
− | Artec Spider – Troubleshooting Checklist | + | Artec Spider |
− | (High-precision, small-object scanner)
| |
| | | |
| #Connection & Power | | #Connection & Power |
Line 138: |
Line 137: |
| ##Perform a calibration using the supplied calibration panel if scans show distortion or misalignment. | | ##Perform a calibration using the supplied calibration panel if scans show distortion or misalignment. |
| #Scanning Conditions | | #Scanning Conditions |
− | ##Ensure the object is matte—apply 3D scanning spray if it’s shiny or transparent.
| |
| ##Keep the scanner 20–30 cm from the object for optimal resolution. | | ##Keep the scanner 20–30 cm from the object for optimal resolution. |
| ##Maintain smooth, steady movement—avoid jerky panning. | | ##Maintain smooth, steady movement—avoid jerky panning. |
Line 144: |
Line 142: |
| ##Add tracking markers or place the object on a textured background if tracking is lost. | | ##Add tracking markers or place the object on a textured background if tracking is lost. |
| ##Reduce object or turntable movement during scanning. | | ##Reduce object or turntable movement during scanning. |
| + | |
| + | Artec Eva |
| + | |
| + | #Connection & Power |
| + | ##Verify USB 3.0 cable is fully seated—Eva draws more power than Spider. |
| + | ##Check for the green LED on the scanner head. |
| + | #Software Setup |
| + | ##Update Artec Studio to the latest version. |
| + | ##Select Eva from the scanner list in the software. |
| + | #Calibration |
| + | ##Eva does not require frequent warm-up, but recalibrate if geometry appears distorted. |
| + | #Scanning Conditions |
| + | ##Maintain 40–100 cm distance from the object. |
| + | ##Ensure good, even lighting; avoid strong shadows or direct sunlight. |
| + | #Tracking Stability |
| + | ##Scan with a background that has texture; plain walls or empty tables can cause tracking loss. |
| + | ##Use larger sweeps to capture big surfaces and avoid sudden movements. |
| + | #Performance & Data Handling |
| + | ##Close other software to give more resources to Artec Studio. |
| + | ##Save large scans frequently to avoid data loss. |
| + | ##If lag occurs, reduce capture resolution or scan sections separately and align later. |
| | | |