Line 91: |
Line 91: |
| | | |
| ==Troubleshooting== | | ==Troubleshooting== |
| + | |
| + | *No weld or weak weld: |
| + | **Check electrode tips for wear, dirt, or oxidation; clean or replace as needed. |
| + | **Verify proper electrode pressure; adjust using the adjustment knob/screw. |
| + | **Ensure cables are securely connected and not damaged. |
| + | *Sparks at handles / arcing: |
| + | **Inspect insulation on handles and tongs; replace if cracked or damaged. |
| + | **Confirm all connections are tight and corrosion-free. |
| + | *Tongs won’t open/close smoothly: |
| + | **Check spring mechanism for damage or debris; clean and lubricate lightly if needed. |
| + | **Ensure pivot points are not seized or misaligned. |
| + | *Overheating tongs: |
| + | **Reduce duty cycle; allow tongs to cool between welds. |
| + | **Check for proper current settings and electrode contact. |
| + | *Uneven welds: |
| + | **Inspect electrode tips for uneven wear; dress or replace as needed. |
| + | **Confirm correct alignment of jaws and consistent pressure. |
| | | |